B09 - Prokon Masonry

MASONRY SECTION DESIGN REINFORCED MASONRY SECTIONS DESIGN | M01

Summary Masonry Section is used to design reinforced masonry beams that span large openings in walls.

What makes this module special?

• 3D representation of the wall section • Detailed calculation output

Detailed Description Masonry Section verifies the resistance of a reinforced masonry beam at a critical section. It is assumed that the loads imposed on the beam cause uniaxial bending and shear.

The following wall types are supported:  Single leaf

 Collar jointed  Grouted cavity

MASONRY SECTION DESIGN REINFORCED MASONRY SECTIONS DESIGN | M01

The design output shows the two failure modes: compression and tension.

Supported Design Codes

Design Codes

SABS 0164 - 1992

MASONRY WALL DESIGN OF LOAD BEARING MASONRY WALLS DESIGN | M02

Summary Masonry Wall is used to design various types of load bearing masonry walls.

What makes this module special?

• 3D representation of the wall section • Detailed calculation output

Detailed Description Masonry Wall determines the resistance of an unreinforced masonry wall, subjected to in-plane axial or out-of-plane loading causing bi-axial bending.

The module supports the following wall types:  Single leaf

 Collar jointed  Grouted cavity

MASONRY WALL DESIGN OF LOAD BEARING MASONRY WALLS DESIGN | M02

The design output provides a tabular and diagrammatic summary of the design.

Supported Design Codes

Design Codes

• •

BS 5628 - 2005 SABS 0164 - 1992

MASONRY FREE WALL DESIGN OF MASONRY FREE-STANDING WALLS DESIGN | M03

Summary Masonry Free Wall can be used to verify the lateral load resistance of wall panels away from wall ends.

What makes this module special?

• 3D representation of the wall section • Detailed calculation output

Detailed Description Masonry Free Wall is used to evaluate masonry walls subject to out-of-plane loads. This module is a standalone program, i.e., it does not post-process results from any of the other analysis modules.

The following wall types are supported:  Solid

 Solid with piers on one side  Solid with piers on both sides  Staggered

Along with multiple load combinations of UDLs, line loads and point loads.

MASONRY FREE WALL DESIGN OF MASONRY FREE-STANDING WALLS DESIGN | M03

The design output provides a tabular and diagrammatic summary of the design.

Supported Design Codes

Design Codes

• •

BS 5628 - 2005 SABS 0164 - 1992

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7

www.prokon.com

Powered by